SVC-01 Cooling & Refrigerant

Full system replacement

Complete removal and replacement of the split air-conditioning system, matching the outdoor condenser and indoor air handler to the building's cooling load, existing ductwork, and electrical supply.

Florida DBPR licences CAC1824292 · RA13067646 · 277 W 26th St, Hialeah

Warning signs & symptoms

If you notice any of these symptoms on your air-conditioning equipment in Hialeah, note them before calling (786) 303-3739.

  • Multiple component failures (compressor, motors, or leaking coils) within a short period.
  • Outdoor condenser fins or indoor evaporator tubing heavily pitted by South Florida heat and humidity.
  • System runs almost continuously during Hialeah afternoons without reaching the thermostat setpoint.
  • Indoor air handler and outdoor condenser are from different generations or mismatched tonnage.

Technical scope & inspection procedure

What a licensed air-conditioning contractor checks and performs during this service.

  1. 01

    Recover existing refrigerant safely and disconnect high-voltage and low-voltage wiring.

  2. 02

    Remove the old outdoor condenser and indoor air handler, inspecting the concrete pad, closet platform, and plenum transitions.

  3. 03

    Set and level the matched condenser and air handler, braze copper line-set connections, and install a new liquid-line filter drier.

  4. 04

    Pressure-test with dry nitrogen, pull a deep vacuum, release refrigerant charge to nameplate subcooling/superheat, and verify airflow and Delta-T.

When targeted repair or service is the right call

A single serviceable part (capacitor, contactor, fan motor, or drain switch) has failed while the compressor and coils remain structurally sound.

When component or system replacement is needed

The compressor is grounded or locked, the evaporator and condenser coils have recurring leaks, or the cabinet and air handler pan are deteriorated.

Technical questions & answers

Why replace both the indoor air handler and outdoor condenser together?

Split air-conditioning systems are engineered as matched pairs. Pairing a new outdoor condenser with an older indoor coil and blower can restrict refrigerant metering, reduce heat transfer, and leave indoor humidity high.

What happens to the copper line-set and drain line during a full replacement?

Accessible copper lines are inspected, flushed, or replaced as needed, a new filter drier is brazed in, and the primary condensate drain and float switch connection are verified before startup.

How is the replacement system tested after installation?

After nitrogen pressure testing and vacuum evacuation, the technician checks static airflow, electrical amp draw, superheat and subcooling, and supply-to-return temperature split.