SVC-02 Cooling & Refrigerant

Compressor Replacement

Diagnosis and replacement of a failed hermetic or scroll compressor in the outdoor condensing unit, including refrigerant recovery, system flush after burnout, new filter drier, and vacuum evacuation.

Florida DBPR licences CAC1824292 · RA13067646 · 277 W 26th St, Hialeah

Warning signs & symptoms

If you notice any of these symptoms on your air-conditioning equipment in Hialeah, note them before calling (786) 303-3739.

  • Outdoor unit hums loudly for a few seconds, clicks off on internal thermal overload, and repeats.
  • Dedicated AC circuit breaker trips as soon as the thermostat calls for cooling.
  • Outdoor fan runs normally, but suction and liquid copper lines remain at ambient outdoor temperature.
  • rattling or metallic grinding from inside the sealed compressor shell during operation.

Technical scope & inspection procedure

What a licensed air-conditioning contractor checks and performs during this service.

  1. 01

    Test compressor windings with an ohmmeter/megohmmeter and verify start capacitor and contactor health first.

  2. 02

    Recover remaining refrigerant, unbraze the failed compressor, and test refrigerant oil for acid after electrical burnout.

  3. 03

    Install the replacement compressor, new liquid-line filter drier, and fresh contactor/run capacitor.

  4. 04

    Pressure-test brazed joints with nitrogen, evacuate to deep vacuum, and weigh in the proper refrigerant charge.

When targeted repair or service is the right call

The outdoor unit fails to start because of a weak run capacitor, pitted contactor, or loose terminal plug while compressor windings test balanced and clean.

When component or system replacement is needed

Megohmmeter testing confirms shorted or grounded motor windings, locked rotor amps persist with a known-good capacitor, or internal valves no longer build pressure differential.

Technical questions & answers

Can a bad capacitor look like a failed compressor?

Yes. When a dual run capacitor loses microfarad capacity, the compressor may hum and trip its thermal overload without starting. Testing the capacitor and contactor comes first before condemning a compressor.

Why is a new filter drier mandatory during compressor replacement?

Opening the sealed refrigerant circuit introduces moisture risk, and a compressor failure can leave debris or acid in the lines. A new liquid-line filter drier protects the replacement compressor.

What causes an AC compressor to fail prematurely in South Florida?

Dirty condenser coils that trap head pressure, running low on refrigerant from an unaddressed leak, failed condenser fan motors, and voltage drops across worn contactors are the primary mechanical causes.