Leak search detection and repair
Pinpointing refrigerant leaks across the indoor evaporator coil, outdoor condenser, copper line-set, and service valves using electronic detection, nitrogen pressure testing, and micro-bubble solutions, followed by targeted repair.
Florida DBPR licences CAC1824292 · RA13067646 · 277 W 26th St, Hialeah
Warning signs & symptoms
If you notice any of these symptoms on your air-conditioning equipment in Hialeah, note them before calling (786) 303-3739.
- You had refrigerant added in the past and the system is blowing warm air or icing up again.
- Dark, slightly greasy oil film around a service valve cap, flare nut, or coil U-bend (refrigerant carries oil with it when it escapes).
- Suction line insulation is encrusted with ice while liquid pressures measure low.
- Hissing sound inside the indoor air-handler cabinet when the compressor shuts off.
Technical scope & inspection procedure
What a licensed air-conditioning contractor checks and performs during this service.
-
01
Inspect accessible copper fittings, Schrader valve cores, distributor tubes, and coil U-bends for refrigerant oil traces.
-
02
Scan the indoor air handler, line-set, and outdoor condenser with a heated-diode or infrared electronic refrigerant leak detector.
-
03
Isolate and pressurize suspect sections with dry nitrogen and pinpoint the exact leak site with micro-bubble solution.
-
04
Braze copper joints, replace leaking valve cores or fittings, pull a deep micron vacuum, and recharge to factory spec.
When targeted repair or service is the right call
The leak is located on a copper line-set joint, filter drier weld, king valve / Schrader core, or an accessible copper U-bend.
When component or system replacement is needed
Multiple pinhole leaks are spread across an aging aluminum or microchannel coil where heat from brazing would open adjacent pores.
Technical questions & answers
Why shouldn't I just keep topping off refrigerant without finding the leak?
A leaking system loses refrigerant oil along with refrigerant, can pull moisture and air into the lines if pressure drops low enough, and will keep freezing up until the leak is sealed.
Where are the most common AC refrigerant leaks found?
The most frequent leak points are indoor evaporator coil U-bends, Schrader valve cores at the outdoor service ports, factory braze joints, and copper lines rubbing against metal clamps.
How do technicians confirm a leak repair holds before recharging?
By pressurizing the circuit with dry nitrogen to test pressure and then pulling a deep vacuum that holds steady on a micron gauge without rising.
Request a quote
Call (786) 303-3739 or use the visual demo form below. No prices are published online.